A canal was designed for a full supply discharge of 60 cumec. The average supply discharge in the canal is 40 cumec. The capacity factor of the canal is:
Concept:Capacity Factor: a) The capacity factor of a canal is the duty based on the discharge at the canal headworks. b) The capacity factor is defined as the ratio of mean supply discharge in a canal during a period to its design full capacity. Capacity Factor of the canal Calculation: Given Data: Full supply discharge = 60 cumec Average supply discharge = 40 cumec Capacity Factor of the canal Capacity Factor of the canal Capacity Factor of the canal = 0.666 Capacity Factor of the canal = 0.67