GATE Mechanical Engineering (ME) 2012 Solved Paper
© examsiri.com
Question : 40 of 65
Marks:
+1,
-0
Water (Cp = 4.18 kJ/kg.K) at 80°C enters a counter flow heat exchanger with a mass flow rate of 0.5 kg/s. Air (Cp = 1 kJ/kg.K) enters at 30°C with a mass flow rate of 2.09 kg/s. If the effectiveness of the heat exchanger is 0.8, the LMTD (in °C) is