GATE Civil Engineering (CE) 2014 Shift 2 Solved Paper
© examsiri.com
Question : 58 of 65
Marks:
+1,
-0
An effluent of a flow rate of 2670 m3/day from a sewage treatment plant is to be disinfected. The laboratory data of disinfection studies with a chlorine dosage of 15 mg/litre yield the model Nt = No e(-0.145t) where Nt = Number of organisms remained at any time t (in 'min')and No = Number of initial organisms at time t = 0. The volume of disinfection unit (in m3) required to achieve a 98 % kill of micro-organisms is ______________
Go to Question: